Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

See <strong>test</strong> analog-<strong>test</strong>call in the Maintenance Comm<strong>and</strong>s for <strong>Avaya</strong> Aura Communication<br />

Manager, Media Gateways <strong>and</strong> Servers (03-300431) for the comm<strong>and</strong> syntax. The comm<strong>and</strong><br />

options <strong>and</strong> the associated <strong>test</strong>s which are executed for <strong>test</strong> analog-<strong>test</strong>call are:<br />

Test Comm<strong>and</strong> Option Test executed<br />

<strong>test</strong> analog-<strong>test</strong>call supervision 844<br />

<strong>test</strong> analog-<strong>test</strong>call full 845<br />

<strong>test</strong> analog-<strong>test</strong>call no-self<strong>test</strong> 846<br />

<strong>test</strong> analog-<strong>test</strong>call no-return-loss 847<br />

<strong>test</strong> analog-<strong>test</strong>call no-st-or-rl 848<br />

These <strong>test</strong>s run on CO-TRK (Analog CO Trunk) <strong>and</strong> TIE-TRK (Analog Tie Trunk).<br />

Table 457: Automatic Transmission Test (#844-848) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be busy with a valid call.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the service state indicates that the port is in use, wait until the port is<br />

idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1001 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1520 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />