19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Table 59: BRI-SET/Adjunct Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

3840-<br />

4095 (o) (p)<br />

0<br />

Associated Test Alarm<br />

Level<br />

BRI-SET<br />

BRI-DAT<br />

BRI-SET, Various Adjuncts<br />

1. Major <strong>and</strong> Minor alarms for this MO may be downgraded to Warning alarms based on the value used with<br />

set options.<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 2: violations of the ISDN-BRI signaling protocol. Timers associated with certain<br />

layer-3 messages have expired before a required response was received. In the following<br />

table, the aux data field indicates what timer has just expired.<br />

Aux Data Timer Type<br />

Alarm<br />

Level<br />

ASAI-ADJ<br />

ATT-ADJ<br />

ATTE-AJ<br />

LGATE-AJ<br />

2 First T303 (SETUP timer)<br />

On/ Off<br />

Board<br />

3 Second T303 (SETUP timer)<br />

4 T305 (DISConnect timer)<br />

5 First T308 (RELease timer)<br />

6 Second T308 (RELease timer)<br />

10 T316 (RESTart timer)<br />

12 T309 (Layer-2 Failure timer)<br />

Recommended Action<br />

16 TM100 (Management Information message Timer 1)<br />

17 TM200 (Management Information message Timer 2)<br />

102 TASAI (ASAI Routing timer)<br />

2 of 2<br />

Issue 5 May 2009 225

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!