MAPD-BD (MAPD Interface Circuit Pack)<br />

3. Remove the DS1 (remove ds1 location) <strong>and</strong> circuit pack (change<br />

circuit-pack location) administration.<br />

If the circuit pack is properly administered <strong>and</strong> the red LED is still on, follow the instructions<br />

for LED alarms without Alarm Log entry or with Error Type 1 in LED Descriptions for <strong>Avaya</strong><br />

Aura Communication Manager Hardware Components (03-602804).<br />

c. Error Type 2: Windows 2000 is down <strong>and</strong> the system attempts to reset the board. If the<br />

reset fails, the board may be bad.<br />

1. Replace the circuit pack.<br />

d. Error Type 18: The circuit pack has been busied out.<br />

1. Release the board (release board location).<br />

e. Error Type 23 <strong>and</strong> 1025: The MAPD-BD circuit pack is not completely administered.<br />

To be fully administered, a MAPD circuit pack must:<br />

● Have an entry in the circuit plan (change circuit-pack)<br />

● Be administered (add ds1 location)<br />

● Be physically inserted into the correct slot<br />

The MAPD circuit pack differs from others in that inserting it into the switch backplane is<br />

not enough to make the board usable.<br />

f. Error Type 125, no Aux Data: A wrong circuit pack is inserted in the slot where this circuit<br />

pack is logically administered. To resolve this problem:<br />

● Remove the wrong circuit pack <strong>and</strong> insert the logically administered circuit pack<br />

or<br />

● Re-administer the slot (change circuit-pack) to match the circuit pack inserted.<br />

g. Error Type 257 see Control Chel Looparound Test (#52) for repair procedures.<br />

h. Error Type 513: Transient hardware problem.<br />

Aux Data 4352 - External RAM failure<br />

Aux Data 4353 - Internal RAM failure<br />

Aux Data 4355 - Internal ROM failure<br />

1. If the same Error Type/Aux Data value occurs more than once in a 24-hour period, the<br />

circuit pack should be replaced. See Shutting Down NT on the TN802 before removing<br />

the circuit pack.<br />

If the MAPD board detects only one of these hardware problems, then the <strong>error</strong> is resolved<br />

when none of these faults are detected for 10 minutes.<br />

i. Error Type 514: LAN External RAM Error; hardware fault in the PPE external RAM, used for<br />

message buffering to <strong>and</strong> from the packet bus. This <strong>error</strong> should not occur regularly.<br />

1. If this <strong>error</strong> occurs 10 times within 30 minutes, replace the circuit pack. See Shutting<br />

Down NT on the TN802 before removing the circuit pack.<br />