Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Hybrid Circuit <strong>and</strong> Conference Circuit Test (#57)<br />

This <strong>test</strong> checks two different port circuit functions. It performs an analog reflective looparound<br />

measurement on the port’s hybrid circuitry. The Conference Circuit <strong>test</strong> performs a conference<br />

<strong>test</strong> on the port’s Network Processing Element (NPE).<br />

For the <strong>test</strong> results to be valid, a voice terminal must be connected to the port being <strong>test</strong>ed. The<br />

<strong>test</strong> instructs the on-board microprocessor to put the port in analog reflective looparound mode.<br />

The Tone-Clock circuit pack supplies a 1004-Hz tone to the port’s listen time slot <strong>and</strong> a GPTD<br />

(General-Purpose Tone Detector) measures the level of the reflected signal appearing on port’s<br />

talk time slot.<br />

The Conference <strong>test</strong> is performed only if the Hybrid Circuit <strong>test</strong> passes. The Conference Circuit<br />

<strong>test</strong> verifies that the NPE can correctly conference several <strong>test</strong> tones together. The <strong>test</strong> is<br />

executed in two parts. The first half of the <strong>test</strong> verifies operation of the NPE’s first three<br />

conference chels, <strong>and</strong> the second half verifies the NPE’s remaining four conference chels. The<br />

<strong>test</strong> puts the NPE in looparound mode <strong>and</strong> instructs it to talk on a specified time slot while<br />

listening to a 1004-Hz tone using the Conference Chels. A GPTD then measures the signal <strong>and</strong><br />

noise levels of the conferenced output <strong>and</strong> reports whether or not these fall within a specified<br />

acceptable range.<br />

This <strong>test</strong> is run on HYB-LINE (Hybrid Line) <strong>and</strong> MET-LINE (MET Line).<br />

Table 307: Hybrid Circuit <strong>and</strong> Conference Circuit Test (#57) 1 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be busy with a valid call.<br />

1. Enter display port location to determine the station<br />

extension of the port.<br />

2. Enter status station to determine the service state of the port.<br />

If the port is in use, wait until the port is idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1001 ABORT System resources required to run this <strong>test</strong> were not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1164 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 4