19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 13: ADX16A-P Error Log Entries<br />

Error<br />

Type<br />

0 1<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended action<br />

0 Any Any Any <strong>test</strong> port location<br />

1 (a) 40977 None<br />

18 0 busyout<br />

station ext<br />

WRN ON release station extension<br />

23 (b) 0 None WRN OFF<br />

130<br />

(c)<br />

257<br />

(d)<br />

513<br />

(e)<br />

1025<br />

(f)<br />

40973 None<br />

Any None<br />

None WRN ON <strong>test</strong> port location<br />

Looparound Test<br />

(#161)<br />

1281 Conference Circuit<br />

Test (#7)<br />

1537 NPE Crosstalk Test<br />

(#6)<br />

MIN<br />

WRN 2<br />

ON <strong>test</strong> port location l r 2<br />

MIN ON <strong>test</strong> port location l r 2<br />

WRN2 MIN ON <strong>test</strong> port location l r 2<br />

2 WRN<br />

1. Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong> sequence. Refer to each<br />

appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.<br />

Notes:<br />

a. Error Type 1 is an inline <strong>error</strong> that can only be resolved over time. No terminal equipment<br />

was present when ringing was attempted. Execute <strong>test</strong> port location<br />

b. Error Type 23: The circuit pack was logically administered but not physically installed. The<br />

alarm will clear when the circuit pack is installed.<br />

c. Error Type 130: The circuit pack was removed or has been insane for more than<br />

11 minutes. To clear the <strong>error</strong>, reseat or replace the circuit pack.<br />

60 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!