Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 509: ATM Board DSP Test (#1293) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2302 ABORT Inconsistent uplink message from the ATM-EI board (an unlikely event).<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2752 ABORT The circuit pack in this location is not a TN2305 or TN2306.<br />

XYZ FAIL There is at least one bad DSP on the board. Values are as follows:<br />

● X indicates the number of bad talker DSPs<br />

● Y indicates the number of bad listener DSPs<br />

● Z indicates the number of bad Echo Canceller DSPs<br />

1. Run the <strong>test</strong>s for the active Tone-Clock in the PN that contains the<br />

indicted circuit pack to verify that dial-tone is supplied. Repair as<br />

needed.<br />

2. If the Tone-Clock is healthy, repeat the <strong>test</strong> on the circuit pack.<br />

3. If this <strong>test</strong> continues to fail, check for service-affecting MINOR<br />

alarms. If a MINOR alarm is raised for Error Type 2817 or 2818,<br />

replace the circuit pack.<br />

4. If a WARNING alarm is raised, this is a non-service-affecting <strong>error</strong>.<br />

The circuit pack can still process calls.<br />

XYZ PASS The <strong>test</strong> passed for some or all DSPs depending on XYZ values. XYZ<br />

indicates the number of talker, listener <strong>and</strong> echo-canceller DSPs for which<br />

the <strong>test</strong> passed, respectively.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

1634 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2