EXP-INTF (Expansion Interface Circuit Pack)<br />

If the red LED remains lit, see the previous note under Expansion Interface LEDs.<br />

Expansion Interface Manual Loopback Procedure<br />

This procedure is to be used when an EI circuit pack cot be <strong>test</strong>ed by software. This occurs<br />

when the EI circuit pack resides in an out-of-service PN. A short length of optical fiber is<br />

required for this procedure.<br />

If this procedure is run on both endpoints of a fiber link (EI circuit packs or SNI circuit packs),<br />

<strong>and</strong> both check out fine, then the failure is most likely in the fiber itself, assuming neither<br />

endpoint circuit pack is busied out <strong>and</strong> the link remains inactive.<br />

1. Busyout the circuit pack (EI or SNI) with busyout board location.<br />

2. Disconnect the transmit <strong>and</strong> receive fiber pair from the lightwave transceiver on the back<br />

of the circuit pack (EI or SNI) slot.<br />

Note: The<br />

Step Action Explanation / Caution<br />

2. Enter busyout pnc.<br />

3. Enter busyout board location. location represents the<br />

cabinet-carrier-slot location of the circuit<br />

pack to be replaced.<br />

4. Replace the circuit pack.<br />

5. Enter release board location. CAUTION: Do not busyout any EI circuit<br />

packs after this point.<br />

6. Enter <strong>test</strong> alarms long clear for<br />

category exp-intf.<br />

7. Wait 5 minutes for SNI-BD, SNI-PEER,<br />

FIBER-LK, <strong>and</strong> DS1C-BD alarms to clear,<br />

or enter clear firmware-counters<br />

a-pnc or b-pnc.<br />

Use the letter designation of the PNC that<br />

holds the replaced component (the<br />

st<strong>and</strong>by PNC).<br />

8. Enter status pnc. If either PNC’s state of health (SOH) is<br />

not “functional,” consult PNC-DUP (PNC<br />

Duplication).<br />

9. Enter release pnc.<br />

Note:<br />

fiber connected to the transmit side of the lightwave transceiver on one EI<br />

circuit pack should be connected to the receive side of the lightwave transceiver<br />

on the circuit pack on the opposite end of the fiber.<br />

2 of 2<br />