Table 291: Digital Station Audits Test (#17) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Digital Station Audits Test (#17)<br />

3 ABORT The EPF has detected an overcurrent condition<br />

DIG-LINE:<br />

1. For a TN754 vintage 13 or earlier Digital Line circuit pack, enter<br />

<strong>test</strong> port location long.<br />

● If Test #11 passes, the EPF condition was cleared. Rerun the<br />

short <strong>test</strong> sequence.<br />

● If Test #11 does not pass, follow the repair procedures for<br />

Digital Line Electronic Power Feed Test (#11)<br />

2. Look for Error Type 769 logged against DIG-LINE <strong>and</strong> follow the<br />

procedures for DIG-LINE (Digital Line).<br />

3. Rerun the <strong>test</strong>.<br />

RDIG-STA:<br />

1. Enter <strong>test</strong> port location long.<br />

● If Test #11 passes, the EPF condition was cleared. Rerun the<br />

short <strong>test</strong> sequence.<br />

● If Test #11 does not pass, follow the repair procedures for<br />

Digital Line Electronic Power Feed Test (#11).<br />

2. Look for Error Type 769 logged against RDIG-STA <strong>and</strong> follow the<br />

procedures for RC-BD (Radio Controller Board).<br />

3. Rerun the <strong>test</strong>.<br />

4 ABORT Internal system <strong>error</strong><br />

1. Resolve any outst<strong>and</strong>ing circuit pack or media module maintenance<br />

problems.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />