Expansion Interface 2-Way Transmission Test (#241)<br />

Expansion Interface 2-Way Transmission Test (#241)<br />

Note:<br />

Note: The term EI applies to both the Expansion Interface (EI) <strong>and</strong> ATM Expansion<br />

Interface (ATM-EI) boards.<br />

This <strong>test</strong> is nondestructive <strong>and</strong> applies to each EI, both active <strong>and</strong> st<strong>and</strong>by.<br />

The EI 2-way transmission <strong>test</strong> is a basic connectivity <strong>test</strong> between two PNs. The <strong>test</strong> first<br />

sends dial tone from the cabinet of the EI circuit pack under <strong>test</strong> through the switch, through the<br />

DS1 converter circuit packs, <strong>and</strong> through another EI circuit pack to a tone detector in the other<br />

cabinet. The connections are then reversed <strong>and</strong> the tone is passed in the opposite direction.<br />

If the <strong>test</strong> either fails or aborts with the above connection, a second PN is chosen (if one is<br />

available <strong>and</strong> the EI circuit pack is In-Service) <strong>and</strong> the same <strong>test</strong> is run on this new connection.<br />

This helps in the isolation of the fault. Since two EI circuit packs are involved in the connection,<br />

either one of them could be at fault. This <strong>test</strong> can help determine which one is actually at fault.<br />

The <strong>test</strong> results indicate if the <strong>test</strong> failed in one or both directions. The <strong>test</strong> aborts if the EIs do<br />

not exist on both ends (for example, the EIs are not administered correctly). If the <strong>test</strong> passes,<br />

the TDM <strong>and</strong> ATM framer interfaces of both EIs are functioning properly.<br />

This <strong>test</strong> runs on ATM-EI (Expansion Interface Circuit Pack) <strong>and</strong> EXP-INTF (Expansion<br />

Interface Circuit Pack).<br />

Table 376: Expansion Interface 2-Way Transmission Test (#241) 1 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic<br />

when the Call Processing Occupancy is greater than 50% or when the<br />

System Management <strong>and</strong> the Call Processing Occupancies together<br />

exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />