Active-St<strong>and</strong>by Peer Link Test (#888)<br />

Active-St<strong>and</strong>by Peer Link Test (#888)<br />

The Active-St<strong>and</strong>by Peer Link <strong>test</strong> is run only in a system equipped with the high- or<br />

critical-reliability configuration. It verifies that a peer link can be set up between the active <strong>and</strong><br />

st<strong>and</strong>by PKT-INTs. A peer link is a logical connection established between the packet bus <strong>and</strong><br />

an IPSI circuit pack’s Packet Interface module for both active <strong>and</strong> st<strong>and</strong>by IPSIs. This link<br />

forwards data <strong>and</strong> control messages between the active <strong>and</strong> st<strong>and</strong>by PKT-INT to prepare for a<br />

pled IPSI interchange. This <strong>test</strong> checks the operation of setting up a Peer Link, <strong>and</strong> verifies that<br />

the active <strong>and</strong> st<strong>and</strong>by IPSI’s Packet Interface modules can communicate over the packet bus.<br />

This <strong>test</strong> checks the functionality of both the active <strong>and</strong> st<strong>and</strong>by Packet Interface modules, but it<br />

is run only on the st<strong>and</strong>by Packet Interface module.<br />

This <strong>test</strong> runs on PKT-INT (Packet Interface).<br />

Table 462: Active-St<strong>and</strong>by Peer Link Test (#888) 1 of 3<br />

Error<br />

Code<br />

1006<br />

1137<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT An IPSI circuit pack’s Packet Interface module is out of service.<br />

1. Enter reset packet-interface location to request a<br />

Packet Interface module reset. See Packet Interface Reset Test<br />

(#889).<br />

1139 ABORT The packet bus is alarmed.<br />

1. Enter display alarms to refer to the Alarm log <strong>and</strong> try to retire<br />

the alarm associated with the packet bus. See PKT-BUS (Packet<br />

Bus).<br />

2. Retry the comm<strong>and</strong> when the alarm associated with the packet bus<br />

is retired.<br />

1335 ABORT Internal IPSI <strong>error</strong>. The Packet Interface module is on the st<strong>and</strong>by IPSI.<br />

1. Enter set ipserver-interface location to make the<br />

st<strong>and</strong>by Packet Interface active.<br />

2. Rerun the <strong>test</strong>.<br />

1336 ABORT Internal system <strong>error</strong>.<br />

1. Enter set ipserver-interface location to make the<br />

st<strong>and</strong>by Packet Interface active.<br />

2. Rerun the <strong>test</strong>.<br />