SN-CONF (Switch Node Configuration)<br />

S8700-series Fiber-PNC<br />

A switch node carrier contains:<br />

SN-CONF (Switch Node Configuration)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

SN-CONF MAJ <strong>test</strong> board location Switch Node Configuration<br />

MIN <strong>test</strong> board location1 1. If the <strong>error</strong> <strong>and</strong> alarm logs display the switch node carrier location UUC (cabinet <strong>and</strong> carrier only), run the<br />

long <strong>test</strong> sequence on the active SNC in the carrier, (slot 10 or 12). If the <strong>error</strong> <strong>and</strong> alarm logs display a<br />

circuit pack location, run the short <strong>test</strong> sequence on the alarmed SNI.<br />

● Up to 16 Switch Node Interface (SNI) TN573 circuit packs in slots 2 through 9 <strong>and</strong> slots 13<br />

through 20<br />

● One or two Switch Node Clock (SNC) TN572 circuit packs in slots 10 <strong>and</strong> 12<br />

● An Expansion Interface (EI) TN570 circuit pack, a DS1 Converter (DS1C) TN574 circuit<br />

pack, or no circuit pack in slot 1<br />

● An optional DS1 converter circuit pack in slot 21<br />

SN-CONF <strong>error</strong>s <strong>and</strong> alarms are generated for two types of failures:<br />

1. Failure of a board in the switch node carrier to insert (be detected by software).<br />

2. A problem was found by running the Configuration Audit (#759). Test 759 is executed for<br />

either an SNI or SNC circuit pack during scheduled maintenance or as part of <strong>test</strong><br />

board location.<br />

For SNI circuit packs, <strong>test</strong> 759 queries the SNI for SNCs in the same switch node carrier,<br />

SNI peers, DS1 converters, <strong>and</strong> EI or SNI neighbors that the SNI can communicate with<br />

<strong>and</strong> compares this data to the administered data.<br />

For SNC circuit packs, <strong>test</strong> 759 queries the SNC for SNCs <strong>and</strong> SNIs in the same switch<br />

node carrier that the SNC can communicate with <strong>and</strong> compares this data to the<br />

administered data.<br />

Switch node carriers are part of port-network connectivity (PNC). For background information<br />

about PNC, refer to the Maintenance Architecture <strong>and</strong> Hardware Configurations chapters <strong>and</strong><br />

related MOs.<br />