Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

DS1 Tie Trunk Seizure Test (#136)<br />

The DS1 Tie Trunk Seizure Test verifies the trunk’s signaling capability. The <strong>test</strong> is composed of<br />

two parts. The first part queries the circuit pack or media module for <strong>error</strong>s. The second part of<br />

the <strong>test</strong> sends a seizure message to the DS1 Interface circuit pack or media module <strong>and</strong><br />

expects an active reply by the DS1 Interface circuit pack or media module. If the system does<br />

not receive any reply <strong>and</strong> the timer expires, the <strong>test</strong> fails.<br />

This second part of this <strong>test</strong> cot be run on a trunk if one of the following cases is true:<br />

1. The trunk direction is administered as an incoming only trunk.<br />

2. The trunk is the 24th port on a DS1 Interface circuit pack or media module which is<br />

administered using 24th common-chel signaling.<br />

3. The trunk has been seized by a normal trunk call.<br />

4. The trunk is administered with maintenance <strong>test</strong> disabled.<br />

5. The outgoing signal type of the trunk is either automatic or immediate-start.<br />

This <strong>test</strong> runs on TIE-DS1 (DS1 Tie Trunk).<br />

Table 336: DS1 Tie Trunk Seizure Test (#136) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> were not available. The port<br />

may be busy with a valid call.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the port is in use, wait until the port is idle before <strong>test</strong>ing.<br />

3. If the port status is active but the port is idle (no calls), check the<br />

<strong>error</strong> log for Error Type 1025. See the <strong>error</strong> log table for a description<br />

of this <strong>error</strong> <strong>and</strong> required actions for this maintenance object. The<br />

port may be locked up.<br />

4. If the port status is idle, retry the comm<strong>and</strong> at 1-minute intervals up to<br />

5 times.<br />

1234 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />