Note: Whenever,<br />

TONE-BD (Tone-Clock Circuit Pack)<br />

Note:<br />

the active archangel detects a loss of clock, it will alternate the state of<br />

the CLKSEL lead until the lost clock signals are restored.<br />

If the IPSI archangel restores the clock signals by activating the [A] IPSI/<br />

Tone-Clock, then Error Type 3857 is reported. If the clock signals are restored by<br />

activating the [B] IPSI/Tone-Clock, then Error Type 3858 is reported. A Cold 2<br />

Restart should occur in a port network immediately after Error Type 3857 or 3858<br />

is reported.<br />

Duplex Reliability — Since there is only one IPSI in the port network, Error Type 3858<br />

can never occur. When Error Type 3857 occurs, it means the [A] IPSI archangel<br />

experienced a loss of clock, but clocking was subsequently restored using the [A] IPSI/<br />

Tone-Clock.<br />

High or Critical Reliability — If the [B] IPSI is active <strong>and</strong> the [A] IPSI is healthy when<br />

Error Type 3857 is reported, then software attempts to initiate an IPSI interchange to<br />

activate the archangel <strong>and</strong> PKT-INT on the [A] IPSI, thereby ensuring that the active<br />

Tone-Clock, PKT-INT, <strong>and</strong> archangel are all on the same IPSI. If the [A] IPSI is unhealthy,<br />

then software initiates a transition to EI-Fallback mode. If the [A] IPSI is active when Error<br />

Type 3857 is reported, it means the archangel for the [A] IPSI had to switch the state of the<br />

CLKSEL lead more than once to restore the lost clock signals.<br />

When Error Type 3858 is reported, if the [A] IPSI is active <strong>and</strong> the [B] IPSI is healthy, then<br />

software attempts to initiate an IPSI interchange to activate the archangel <strong>and</strong> PKT-INT on<br />

the [B] IPSI. If the [B] IPSI is unhealthy, then software initiates a transition to EI-Fallback<br />

mode. If the [B] IPSI is active when Error Type 3858 is reported, it means the archangel for<br />

the [B] IPSI had to switch the state of the CLKSEL lead more than once to restore the lost<br />

clock signals.<br />

For the high <strong>and</strong> critical reliability configurations, Error Type 2305 should be logged<br />

against TONE-BD for the st<strong>and</strong>by IPSI/Tone-Clock after Error Type 3857 or 3858 is<br />

reported.<br />

s. Error Type 3872: an IPSI or Tone-Clock circuit pack had a loss of Data Clocks. This <strong>error</strong><br />

will impact mainly users on station connected to Digital circuit packs. These users could be<br />

with out service. If <strong>error</strong> 2049 is also logged see Note (k).<br />

t. Error Type 3999: the circuit pack sent a large number of control chel messages to the<br />

switch within a short period of time. If Error Type 1538 is also present, then the circuit pack<br />

was taken out of service due to hyperactivity. If Error Type 1538 is not present, then the<br />

circuit pack has not been taken out of service, but it has generated 50% of the messages<br />

necessary to be considered hyperactive. This may be completely normal during heavy<br />

traffic periods. However, if this Error Type is logged when the circuit pack is being lightly<br />

used, it may indicate a problem with the circuit pack or the equipment attached to it.<br />