DID-DS1 (Direct Inward Dial Trunk)<br />

MO Name in Log Alarm<br />

Level<br />

DID-DS1 MAJ 1<br />

MIN<br />

DID-DS1 (Direct Inward Dial Trunk)<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

<strong>test</strong> trunk grp#/mem# long Direct Inward Dial Trunk<br />

WRN <strong>test</strong> trunk grp#/mem#<br />

1. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by set options<br />

<strong>and</strong> that at least 75 percent of the trunks in this trunk group are alarmed.<br />

The DID-DS1 trunk provides a digital Direct Inward Dial (DID) trunk from a CO switch to the<br />

system through a DS1 link. A 24-chel DS1 link can support up to 24 DID-DS1 trunk calls<br />

simultaneously. A 32-chel link can support up to 30.<br />

A DID-DS1 trunk can be used for digitized voice <strong>and</strong> data communications with DS1 signaling<br />

mode (for example, common-chel signaling). The TN767 <strong>and</strong> TN464 circuit packs <strong>and</strong> the DS1<br />

Interface Media Module support wink-start <strong>and</strong> immediate-start trunks <strong>and</strong> Communication<br />

Manager signaling. Throughout this section, the term DS1 applies to all. For more information,<br />

see one of the following maintenance objects:<br />

Circuit Pack/Media Module Maintenance<br />

Object<br />

TN767 DS1 Interface Circuit Pack DS1-BD<br />

TN464 UDS1 Interface Circuit Pack UDS1-BD<br />

DS1 Interface Media Module MG-DS1<br />

Not all <strong>test</strong>s that run on circuit packs are applicable to media modules. These <strong>test</strong>s will abort<br />

with <strong>error</strong> code 1412. This <strong>error</strong> can be ignored.<br />

Two trunk service states are specified in the DID-DS1 trunk maintenance:<br />

out-of-service The trunk is in a deactivated state <strong>and</strong> cot be used for<br />

incoming calls.<br />

in-service The trunk is in an activated state <strong>and</strong> can be used for<br />

incoming calls.<br />

If a DS1 is out-of-service, every trunk on the circuit pack or media module is put into the<br />

out-of-service state, <strong>and</strong> a Warning alarm is raised.<br />