Communication Manager Maintenance Object Repair Procedures<br />

ATM-TRK-related comm<strong>and</strong>s<br />

Table 53: ATM CES troubleshooting comm<strong>and</strong>s lists some comm<strong>and</strong>s that can be useful in<br />

troubleshooting ATM <strong>error</strong>s <strong>and</strong> alarms.<br />

Table 53: ATM CES troubleshooting comm<strong>and</strong>s<br />

Comm<strong>and</strong> Description<br />

display circuit-packs cabinet Shows the circuit packs in the cabinet,<br />

identifying ATM trunk as well as ATM-EI<br />

boards. “ATM Interface” boards have not been<br />

administered as CES or PNC.<br />

display atm ports location Shows the 256 ports on the ATM board with<br />

the corresponding signaling <strong>and</strong> trunk group.<br />

list configuration atm Lists the ATM boards, identifying equipment<br />

location, board code, type, <strong>and</strong> vintage.<br />

list configuration trunks Lists boards identifying assigned ports. While<br />

the ATM board is listed, the 256 ports are not.<br />

busyout/release atm<br />

signaling-group<br />

Error log entries <strong>and</strong> recommended actions<br />

Busyout or release of an ATM signaling group<br />

within a trunk group.<br />

status atm signaling-group Show current status of an ATM signaling<br />

group.<br />

status trunk-group Shows status of the trunk group (ATM<br />

signaling groups are part of trunk groups).<br />

Table 54: ATM-TRK Error Log entries 1 of 3<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 0 Any Any <strong>test</strong> board location<br />

1(a) None MIN ON<br />

186 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />