j. Error Type 2049:<br />

S8700-series Fiber-PNC<br />

TDM-CLK (TDM Bus Clock)<br />

The Tone-Clock circuit in the master port network was unable to detect the incoming<br />

synchronization signal, but the other tone-clock was able to detect the references. If the<br />

Aux Data is 0, the problem is with the signal on the primary. If the Aux Data is 1, the<br />

problem is with the signal on the secondary. The system should switch clocks in this<br />

situation.<br />

1. If this <strong>error</strong> is against PN 1’s clock board <strong>and</strong> the system is using a Stratum-3 clock,<br />

check the cabling that brings the Stratum-3 signal to this clock board.<br />

2. Replace the current st<strong>and</strong>by IPSI or Tone-Clock circuit pack. See Replacing the IPSI<br />

or Tone-Clock Circuit Pack.<br />

k. Error Type 2305:<br />

S8700-series Fiber-PNC<br />

The indicated Tone-Clock circuit is an active slave Tone-Clock that has detected a loss of<br />

timing signal from its EXP-INTF synchronization source. (A slave Tone-Clock resides in a<br />

PN that does not contain the system’s reference synchronization source.)<br />

1. Enter display <strong>error</strong>s <strong>and</strong> display alarms, <strong>and</strong> follow the repair procedures for<br />

EXP-INTF (Expansion Interface Circuit Pack), TDM-CLK (TDM Bus Clock), <strong>and</strong><br />

TONE-BD (Tone-Clock Circuit Pack) <strong>error</strong> log entries that have on-board alarms.<br />

2. If the 2305 <strong>error</strong>s persist, follow the repair procedures for EXP-INTF (Expansion<br />

Interface Circuit Pack) <strong>error</strong> log entries 257, 769, or 770, or any <strong>error</strong>s logged against<br />

SNI-BD (SNI Circuit Pack), SNC-BD (Switch Node Clock Circuit Pack), or FIBER-LK<br />

(Fiber Link).<br />

3. If the 2305 <strong>error</strong>s persist:<br />

a. For Port Networks with more than one Tone-Clock circuit, execute <strong>test</strong><br />

synchronization r 10 to see if new 2305 <strong>error</strong>s against TDM-CLK were<br />

reported. If not, execute reset pnc interchange <strong>and</strong> <strong>test</strong><br />

synchronization r 10 again, <strong>and</strong> recheck for new 2305 <strong>error</strong>s against<br />

TDM-CLK<br />

b. For Port Networks with a single Tone-Clock circuit, execute <strong>test</strong><br />

synchronization r 10 to see if new 2305 <strong>error</strong>s were reported.<br />

If no new instances of the 2305 <strong>error</strong>s were logged for either <strong>test</strong>, enter <strong>test</strong><br />

tone-clock location long clear to clear the TDM-CLK <strong>error</strong>s. The procedure<br />

is complete.<br />

4. For Port Networks with more than one Tone-Clock circuit:<br />

a. Enter set tone-clock location to interchange the Tone-Clocks.<br />

Issue 5 May 2009 969