19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

ADX8D-PT (AUDIX Digital Port)<br />

The ADX8D-PT MO represents a port on a TN566/TN2169 EMBEDDED AUDIX circuit pack<br />

operating in DP (digital-port) mode. The maintenance strategy for ports on the TN566 operating<br />

in control-link mode is described in ADX16D-P (16-Port AUDIX Digital Port).<br />

The <strong>test</strong>s apply only to switch-side maintenance that <strong>test</strong>s a circuit pack’s components related<br />

to the TDM-bus interface. The AUDIX system has an extensive maintenance strategy that is<br />

described in DEFINITY® AUDIX Maintenance, 585-300-110.<br />

AUDIX resides on a combined pair of circuit packs: the TN566 MFB (multifunction board) <strong>and</strong><br />

the TN2169 ALB (alarm board). The 2 boards occupy 5 slots, but only 1 slot is functional as far<br />

as the switch is concerned. The other 4 slots are seen by the switch as “AUDIX-reserved” slots<br />

(or ADXDP-RS/ADX8D-RS).<br />

In DP mode, the TN566 pack supports up to 8 voice ports, each with a primary <strong>and</strong> a secondary<br />

information chel. Ports are administered in increments of two. When a call to a station with an<br />

AUDIX login is not answered, AUDIX answers the call using one of the available voice ports.<br />

Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.<br />

CAUTION: Always<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ADX8D-PT MIN <strong>test</strong> port location l AUDIX digital port<br />

WRN <strong>test</strong> port location<br />

! CAUTION:<br />

shut down AUDIX first before removing circuit packs. Follow instructions<br />

on the TN566/TN2169 faceplate:<br />

● Remove EMBEDDED AUDIX circuit packs<br />

● Cycle power to a carrier containing EMBEDDED AUDIX circuit packs<br />

● Remove power to a carrier containing EMBEDDED AUDIX circuit packs<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 12: ADX8D-PT Error Log Entries 1 of 2<br />

Error Type Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

54 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 2

Hooray! Your file is uploaded and ready to be published.