Communication Manager Maintenance Object Repair Procedures<br />

ADX16D-B (16-Port AUDIX Circuit Pack)<br />

MO Name in Log Alarm<br />

Level<br />

ADX16D-B MIN<br />

WRN<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

<strong>test</strong> board location AUDIX circuit pack<br />

The ADX16D-B MO represents a TN566/TN2169 EMBEDDED AUDIX circuit pack combination<br />

operating in 16-port mode digital (DP).<br />

For circuit-pack-level problems, see XXX-BD (Common Port Circuit Pack/Media Module).<br />

Port-level maintenance is covered by ADX16D-P (16-Port AUDIX Digital Port).<br />

EMBEDDED AUDIX consists of two circuit packs that occupy 5 slots on a port carrier. The <strong>test</strong>s<br />

apply only to switch-side maintenance that <strong>test</strong>s a circuit pack’s components related to the<br />

TDM-bus interface. The AUDIX system has an extensive maintenance strategy of its own that is<br />

described in DEFINITY® AUDIX Maintenance, 585-300-110.<br />