the port is an ABRI-PORT/LGATE-PT/ATTE-PT/ATT-PORT). If this problem persists,<br />

replace the endpoint or endpoints associated with this port. If replacing the endpoints does<br />

not fix the problem, follow normal escalation procedures.<br />

h. Error Type 1537: the port receives an invalid frame over the D-Chel. When CRC <strong>error</strong>s<br />

exceed five within 15 minutes, the port is taken out of service for five seconds. If five more<br />

CRC <strong>error</strong>s are received within 15 minutes of the first set of five <strong>error</strong>s, the port is taken out<br />

of service for one minute. If five more CRC <strong>error</strong>s are received within 15 minutes of the last<br />

five, the port is taken out of service for 15 minutes.<br />

This <strong>error</strong> is most likely due to a problem with the wiring to the set or adjunct, interference<br />

on the wiring due to a noise source, or no termination (an open circuit). It usually does not<br />

indicate a problem with the circuit pack.<br />

● Check the wiring to the endpoints or the adjunct.<br />

● If the problem persists, replace the endpoints or adjuncts, or escalate the problem.<br />

i. Error Type 1793: the BRI Port Local TDM Looparound Test (#619) fails. Run the long <strong>test</strong><br />

sequence, <strong>and</strong> note the results of Test #619.<br />

There are no recommended actions for the following Error Types. The Error Types are<br />

simply provided as additional data that may prove useful while troubleshooting.<br />

j. Error Type 3841: a Layer 1 Transmission <strong>error</strong> is detected for the port. Run the long <strong>test</strong><br />

sequence, <strong>and</strong> note the results of the Layer 1 Transmission Error Counter Test (#624).<br />

k. Error Type 3842: A BRI port supports up to three Terminal Endpoint Identifiers (TEIs). This<br />

<strong>error</strong> occurs when the switch receives a request for a fourth TEI on a port. Check the<br />

number of endpoints administered for this port.<br />

l. Error Type 3843: a SPID initialization request is made from an endpoint <strong>and</strong> the switch<br />

determines that the SPID value is invalid or is a duplicate of another SPID that is already<br />

initialized at Layer 3 on the port. Check the administration of the endpoints.<br />

m. Error Type 3844: the circuit pack detects an overflow of its receive buffers. Run the long<br />

<strong>test</strong> sequence, <strong>and</strong> note the results of the Receive FIFO Error Counter Test (#625).<br />

n. Error Type 3845: the BRI Port Local LAN Looparound Test (#618) fails. Run the long <strong>test</strong><br />

sequence, <strong>and</strong> note the results of Test #618.<br />

o. Error Type 3846: most likely occurs when the Terminal Endpoint Identifier (TEI)<br />

administered for the ASAI or <strong>Avaya</strong> endpoint does not match the TEI administered in the<br />

ASAI or <strong>Avaya</strong> adjunct. Check the switch administration of the TEI against that of the<br />

adjunct <strong>and</strong> make sure that both are using the same TEI.<br />

p. Error Type 384: sets on the port do not support layer-3 initialization. Consult the Service<br />

Set documentation.<br />