Table 495: ATM Board Reset (#1256) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the required system resources<br />

1. Retry the comm<strong>and</strong> up to 5 times at 1-minute intervals.<br />

2. If the <strong>test</strong> continues to abort escalate the problem.<br />

ATM Board Reset (#1256)<br />

1005 ABORT Wrong circuit pack configuration to run this <strong>test</strong>. The ATM CES Trunk<br />

Interface circuit pack provides timing for the system <strong>and</strong> cot be reset<br />

without major system disruptions.<br />

1. Set synchronization to another ATM CES trunk circuit pack or to the<br />

Tone-Clock circuit pack <strong>and</strong> <strong>test</strong> again.<br />

1015 ABORT The ATM-TRK circuit pack has not been busied out.<br />

1. Busyout out the circuit pack with busyout board location<br />

2. Repeat the <strong>test</strong> with <strong>test</strong> board location long<br />

1386 ABORT No Active EAL to the board. This <strong>error</strong> applies only if the board under <strong>test</strong> is<br />

in a PN. Check the <strong>error</strong> logs for SYS-LINK (System Links) <strong>error</strong>s against<br />

the PN where the ATM-EI resides, <strong>and</strong> take appropriate diagnostic action for<br />

the SYS-LINK.<br />

1407 ABORT This <strong>test</strong> cot be run on an ATM-EI board that is on the active PNC because<br />

it cot be busied out. This <strong>error</strong> code indicates that PNC duplication is<br />

enabled.<br />

1. Attempt to perform a PNC interchange with<br />

reset pnc interchange<br />

2. If the PNC interchange is successful, busyout the original<br />

ATM-Expansion Interface circuit pack with busyout board<br />

location (address of the original ATM-EI board)<br />

3. Retry the comm<strong>and</strong>.<br />

2000 ABORT Did not receive the response in the allowed time.<br />

1. Verify that the board is seen by the system with list config all.<br />

2. If the board is visible, run the <strong>test</strong> again. If the same abort code<br />

recurs, escalate the problem.<br />

3. If the board is not visible to the system with list config all,<br />

reseat the board.<br />

4. If the board is still not recognized by the system, replace the board.<br />

1 of 2<br />