Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 400: Maintenance/Test Circuit Pack Query Test (#572) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

xyzz FAIL The Maintenance/Test packet bus port has detected faults on the Packet<br />

Bus. The Error Codes are interpreted as follows:<br />

1yzz - The Maintenance/Test packet bus port has reconfigured the packet<br />

bus around the faulty leads. This action only occurs in a high- or<br />

critical-reliability system (duplicated PNC).<br />

2yzz - The Maintenance/Test packet bus port is unable to correct every<br />

Packet Bus fault it has detected.<br />

x0zz - None of the packet bus faults are open faults.<br />

x1zz - At least some of the packet bus faults are open faults. Look for<br />

Error Type 2305 in the Error Log. The Aux Data value indicates the<br />

number of open leads.<br />

xyzz - The last two digits of the Error Code indicate the total number of<br />

faulty packet bus leads detected.<br />

Examples:<br />

Packet Circuit Pack Audit Test (#573)<br />

Error Code 2003 FAIL: The Maintenance/Test packet bus port has<br />

detected 3 faulty leads. None of them are opens. At least one was<br />

unable to be corrected.<br />

Error Code 1103 FAIL: The Maintenance/Test Packet Port has<br />

detected 3 faulty leads. At least one is an open. The Maintenance/<br />

Test circuit pack was able to correct all of them by reconfigured.<br />

See Isolating <strong>and</strong> repairing packet-bus faults in Maintenance Procedures<br />

for <strong>Avaya</strong> Aura Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432)<br />

PASS No faults have been detected on the packet bus by the Maintenance/Test<br />

circuit pack. The packet bus is operating correctly.<br />

This <strong>test</strong> determines whether Packet circuit packs have reported Packet Bus-related inline<br />

<strong>error</strong>s within the last minute. If so, the failure code indicates whether one or more than one<br />

circuit pack has reported such failures.<br />