Steps Comments<br />

Enter change circuit-packs<br />

cabinet #. Update the screen to<br />

show that TN1654 boards are now<br />

being used instead of TN574 boards.<br />

Also update the connected SNI, if<br />

applicable, to suffix B.<br />

Enter add fiber-link fiber# to<br />

re-add the fiber-link using TN1654 DS1<br />

converter circuit packs.<br />

Enter <strong>test</strong> alarms long clear<br />

for category exp-intf.<br />

Wait 5 minutes for SNI-BD, FIBER-LK<br />

AND DS1C-BD alarms to clear, or<br />

enter clear firmware-counters<br />

a-pnc<br />

Cabinet # represents the cabinet associated with a<br />

DS1 converter board. The change circuit-packs<br />

screen needs to be updated for both DS1 converter<br />

boards. Also, if needed, re-add translations for<br />

connected EI boards.<br />

Fiber# represents the fiber-link number associated<br />

with the TN574 DS1 converter complex that is being<br />

upgraded to a TN1654 DS1 converter complex<br />

382 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />