Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Circuit Pack Restart Test (#594)<br />

This <strong>test</strong> is destructive.<br />

Run this <strong>test</strong> to reset the circuit pack only if there are PPCPU <strong>error</strong>s. This <strong>test</strong> fails if the circuit<br />

pack does not return to a sane state after being reset. The circuit pack resets through the SAKI<br />

Sanity <strong>test</strong> (#53).<br />

This <strong>test</strong> runs on VAL-BD (Voice announcements over LAN Circuit Pack).<br />

Table 404: Circuit Pack Restart Test (#594)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the problem persists, escalate the problem.<br />

1015 ABORT Port is not out-of-service.<br />

1. Busyout the circuit pack with busyout board location.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

3. If the problem persists, escalate the problem.<br />

1966 ABORT The board is in the process of running the autosave comm<strong>and</strong> to save<br />

announcements.<br />

1. Retry the comm<strong>and</strong> again later.<br />

2100 ABORT Could not allocate the necessary system resources to run <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the problem persists, escalate the problem.<br />

1<br />

2<br />

FAIL The circuit pack failed to reset.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the problem persists, pull out <strong>and</strong> reseat the circuit pack.<br />

3. Rerun the <strong>test</strong>. If the problem persists, replace the circuit pack.<br />

PASS The circuit pack initialized correctly.<br />

1. Enter release board location to put the board in-service.<br />

1382 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers