Table 440: SNI-BD Configuration Audit (#759) 5 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Configuration Audit (#759)<br />

138 FAIL The physical neighbor location does not match administered neighbor<br />

location. The carrier <strong>and</strong> slot of the administered neighbor do not match<br />

the carrier <strong>and</strong> slot of the physical neighbor.<br />

1. Enter list fiber-link, <strong>and</strong> verify that the fiber-optic cable <strong>and</strong><br />

metallic cable connections are installed as administered.<br />

2. If the problem does not seem to be caused by a physical connection<br />

problem or an administration problem, replace the neighbor circuit<br />

pack. It is possible for the neighbor circuit pack to have a hardware<br />

problem that causes it to report a wrong Angel address (physical<br />

carrier/slot address) to software.<br />

139 FAIL The SNI is administered as connected to a DS1C but is not physically<br />

connected to a DS1C.<br />

If a DS1C should not be connected to this SNI, change administration to<br />

remove the DS1 converter complex from the fiber link associated with this<br />

SNI:<br />

1. Enter list fiber-link to determine the fiber associated with the<br />

SNI.<br />

2. Enter remove fiber-link to remove the fiber.<br />

3. Enter add fiber-link to add the fiber back, <strong>and</strong> do not<br />

administer the DS1 converter complex at this time.<br />

140 FAIL The SNI is physically connected to a DS1C but is not administered to be<br />

connected to a DS1C.<br />

Either add the DS1 converter complex to the fiber that this SNI is<br />

associated with by:<br />

1. Enter list fiber-link to determine the fiber associated with the<br />

SNI.<br />

2. Enter remove fiber-link to remove the fiber.<br />

3.<br />

Or:<br />

Enter add fiber-link to add the fiber back, <strong>and</strong> administer the<br />

DS1 converter complex.<br />

4. Remove the DS1C connection, <strong>and</strong> connect the SNI directly to its<br />

administered fiber endpoint.<br />

5. Verify that the fiber-optic <strong>and</strong> metallic cable connections are installed<br />

as administered by entering list fiber-link.<br />

5 of 6<br />