YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Auxiliary Trunk Diagnostic Test (#114)<br />

The system sends a message to the on-board microprocessor to operate a relay in the port<br />

circuit. If ground is detected, the <strong>test</strong> passes. This <strong>test</strong> runs on the AUX-TRK (Auxiliary Trunk)<br />

maintenance object.<br />

Table 324: Auxiliary Trunk Diagnostic Test (#114)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be busy with a valid call.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service<br />

state of the port. If the port is in use, wait until it is idle.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service<br />

state of the port. If the port is in use, wait until it is idle.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The <strong>test</strong> failed to detect ground.<br />

1. Rerun the <strong>test</strong>.<br />

2. If the <strong>test</strong> fails again, replace the circuit pack.<br />

PASS This <strong>test</strong> passed. Ground was detected.<br />