Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 437: SNI Destructive Facility On-board Test (#757) 3 of 4<br />

Error<br />

Code<br />

2306 ABORT The SNI circuit pack is not responding to <strong>test</strong> requests sent by software.<br />

1. Run <strong>test</strong> led switch-node for the switch node where the SNI<br />

board(s) reside to verify whether their LEDs light.<br />

2. If LEDs light on the other boards in the same carrier but not on this<br />

board, enter <strong>test</strong> board location long to run Test #760 for<br />

the active SNC in this carrier. Wait 5 minutes, <strong>and</strong> try step 1 again.<br />

If the board’s LEDs still do not light, replace the board. Replacing<br />

an SNI may be service interrupting. Refer to SNI-BD (SNI Circuit<br />

Pack) for the procedure to replace an SNI.<br />

3. If none of the LEDs light for the boards in the same carrier as this<br />

board, fix any problems associated with the connectivity of this<br />

carrier to the server.<br />

a. Check list fiber-link to see the fiber connections to this<br />

carrier.<br />

b. Check the LEDs on every SNI <strong>and</strong> EI, <strong>and</strong> fix any fiber<br />

problems.<br />

c. Enter display <strong>error</strong>s, <strong>and</strong> follow the repair procedures for<br />

any EXP-INTF <strong>error</strong> entries associated with the controlling<br />

IPSI connected PN.<br />

d. Follow the repair procedures if there are <strong>error</strong>s for any of the<br />

following:<br />

127<br />

227<br />

Test<br />

Result<br />

Description / Recommendation<br />

● SYNC (Port Network Synchronization)<br />

● SNI-BD (SNI Circuit Pack)<br />

● SNC-BD (Switch Node Clock Circuit Pack)<br />

● FIBER-LK (Fiber Link)<br />

● SNI-PEER (SNI Peer Link)<br />

e. For SNI-BD, see Switch Node Interface Manual Loopback<br />

Procedure to determine whether the circuit pack or the fiber<br />

connection is faulty.<br />

FAIL The data is not correctly looped around on Endpoint 1 of the fiber link.<br />

The data is not correctly looped around on Endpoint 2 of the fiber link.<br />

1. Enter list fiber-link to display fiber link endpoints.<br />

2. Replace the SNI circuit pack.<br />

1456 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />