WARNING: The facility fault sectionalization technique disrupts service. When you perform<br />

the looparound on a facility, make sure it is not the on-line synchronization<br />

reference or a system outage will occur.<br />

When you use this technique to investigate problems on facilities with multiplex or DACS<br />

equipment, the technique becomes cumbersome because every 64-kbps (B-Chel) or subrate<br />

chel corresponding to the DS1 facility needs to be looped around.<br />

Figure 85: Manual Looparound for Facility Fault Sectionalization shows a sequence of units (1<br />

though n) that may be connected as the on-site equipment. A typical example is the case where<br />

the only on-site equipment is chel-terminating equipment designated Unit #1. A more complex,<br />

less typical example might have a DACS as Unit #1, a protection switch as Unit #2, <strong>and</strong> a<br />

DS1-level microwave radio system as Unit #3.<br />

The flowchart in Figure 86: Facility Fault Sectionalization gives an overview of the facility fault<br />

sectionalization technique. It is important that you know the configuration <strong>and</strong> wiring of the<br />

equipment for the problem facility in order to support this technique.<br />

Figure 85: Manual Looparound for Facility Fault Sectionalization<br />

Switch<br />

TN722,<br />

TN767, or<br />

TN464<br />

DS1 interface<br />

Manually<br />

wired<br />

loop-around<br />

Pairs open<br />

at next unit<br />

Next unit<br />

(#1)<br />

Next unit<br />

(#N)<br />

Since the technique is time consuming, fix any DS1-BD (DS1 Interface Circuit Pack), UDS1-BD<br />

(UDS1 Interface Circuit Pack), STRAT-3 (Stratum-3 Clock), or SYNC (Port Network<br />

Synchronization) <strong>error</strong>s first that are not slip <strong>error</strong>s.<br />

912 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Span<br />

line<br />

side<br />

sync4 LJK 072501