Table 139: INADS Link Test Error Log Entries 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

INADS (INADS Link)<br />

4 0 The alarm receiver did not answer the <strong>test</strong> call.<br />

1. Verify that the alarm receiver is up.<br />

2. Verify the accuracy of the alarm receiver’s phone number <strong>and</strong> the<br />

system’s product ID using the Maintenance-Related System<br />

Parameters screen.<br />

3. Enable alarm origination using the Maintenance-Related System<br />

Parameters screen.<br />

4. Test the SYSAM (System Access Maintenance) by entering<br />

<strong>test</strong> maintenance a | b.<br />

5. Retry the comm<strong>and</strong>.<br />

5 0 The alarm receiver’s phone number is not assigned.<br />

1. Assign the alarm receiver’s phone number via the Maintenance-Related<br />

System Parameters screen.<br />

2. Retry the comm<strong>and</strong>.<br />

6 0 The alarm receiver did not return an acknowledgment for the “<strong>test</strong> inads<br />

alarm” message.<br />

1. Verify the accuracy of the alarm receiver’s phone number <strong>and</strong> the<br />

system’s product ID via the Maintenance-Related System Parameters<br />

screen.<br />

2. Verify that the alarm receiver is up.<br />

3. Retry the comm<strong>and</strong>.<br />

7 0 The alarm receiver returned a negative acknowledgment for the TESTING<br />

INADS LINK message.<br />

1. Verify that the product IDs match in the customer’s switch <strong>and</strong> the alarm<br />

receiver’s database. Use the Maintenance-Related System<br />

Parameters screen to identify the product ID of the switch.<br />

2. Rerun the <strong>test</strong>.<br />

8 0 Internal system <strong>error</strong>. System received an invalid return code.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

9 0 Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 of 3<br />