Table 99: DS1C-BD Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

769 (q) 7 Failure Audit <strong>test</strong><br />

(#949)<br />

1281(r) Failure Audit <strong>test</strong><br />

(#949)<br />

1537 (s) Failure Audit <strong>test</strong><br />

(#949)<br />

1793 (t) Failure Audit <strong>test</strong><br />

(#949)<br />

2049 (u) Failure Audit <strong>test</strong><br />

(#949)<br />

3329 (v) Failure Audit <strong>test</strong><br />

(#949)<br />

On/Off<br />

Board<br />

DS1C-BD (DS1 Converter Circuit Pack)<br />

Recommended Action<br />

MIN ON <strong>test</strong> board location<br />

MIN OFF <strong>test</strong> board location<br />

MAJ OFF <strong>test</strong> board location<br />

MAJ OFF <strong>test</strong> board location<br />

MAJ OFF <strong>test</strong> board location<br />

WRN OFF <strong>test</strong> board location<br />

2 of 2<br />

Notes:<br />

When problems persist, resetting the DS1 converter circuit pack via reset board may<br />

temporarily resolve the <strong>error</strong> condition <strong>and</strong> restore service until further assistance is provided.<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

b. Error Type 1: If the alarm is on board, then a major hardware <strong>error</strong> has occurred in a<br />

common part of the circuit pack, not circuit or packet specific. Replace the DS1 converter<br />

circuit pack.<br />

If the alarm is off board, then either a major hardware <strong>error</strong> has occurred in a common part<br />

of the circuit pack, or a good clock signal cot be recovered from the synchronization<br />

source. The synchronization source can be the fiber link or any one of the DS1 facilities.<br />

1. Enter display <strong>error</strong>s <strong>and</strong> follow the associated repair procedures for any SYNC<br />

(Port Network Synchronization), TDM-CLK (TDM Bus Clock), <strong>and</strong> SNC-BD (Switch<br />

Node Clock Circuit Pack) <strong>error</strong>s.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> follow the associated repair procedures for any<br />

FIBER-LK (Fiber Link) <strong>and</strong> DS1-FAC (DS1 Facility) <strong>error</strong>s.<br />

3. If the problem persists, replace the DS1 converter circuit pack.<br />

c. Error Type 18: the DS1 converter circuit pack has been busied out via busyout board.<br />

To resolve this <strong>error</strong>, release the DS1 converter circuit pack via the release board.<br />

Issue 5 May 2009 391