DS1 Translation Update Test (#146)<br />

DS1 Translation Update Test (#146)<br />

The DS1 Translation Update Test sends the board-level information specified by System<br />

Administration to the DS1/UDS1 Interface circuit pack or media module. Translation includes<br />

the following data (see the output of display ds1 location): DS1 Link Length between two<br />

DS1 endpoints, Synchronization Source Control, All Zero Suppression, Framing Mode,<br />

Signaling Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.<br />

If a DS1/UDS1 circuit pack is combined with a 120A CSU module or the 401A T1 sync splitter to<br />

screen an Integrated CSU module/T1 sync splitter, this <strong>test</strong> will also send the administration for<br />

the Integrated CSU to the circuit pack to assure the board’s translations are correct. The<br />

administration of the CSU module/T1 sync splitter is done using the DS1 Circuit Pack<br />

administration screen. Translation for the CSU module/T1 sync splitter includes the following<br />

data: Transmit LBO, Receive ALBO, Supply CPE Loopback Jack Power.<br />

This <strong>test</strong> is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MAPD-BD (MAPD Interface Circuit Pack)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

Table 345: DS1 Translation Update Test (#146)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL Internal system software <strong>error</strong>.<br />

1. Enter display ds1 location to verify the DS1 board<br />

translation.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS Translation data has been downloaded to the DS1 board successfully.<br />

0 NO<br />

BOARD<br />

See NO BOARD for the repair procedures.<br />

Issue 5 May 2009 1257