Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Modem Pool Conference Test (#97)<br />

This <strong>test</strong> is destructive.<br />

The Modem Pool Conference Test checks most of the switching <strong>and</strong> gain control functions<br />

provided by the NPE circuit in the analog section of the conversion resource. This <strong>test</strong><br />

conferences a 1004-Hz tone through the NPE, looping it back so that it can be verified with a<br />

Tone Detector circuit<br />

This <strong>test</strong> runs on MODEM-PT (Modem Pool Port).<br />

Table 320: Modem Pool Conference Test (#97) 1 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources required for this <strong>test</strong> are not available.<br />

1. Determine whether the port is available for <strong>test</strong>ing.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be in use on a valid call.<br />

1. Determine whether the port is available for <strong>test</strong>ing.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic<br />

when the Call Processing Occupancy is greater than 50% or when the<br />

System Management <strong>and</strong> the Call Processing Occupancies together<br />

exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1192 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />