To administer a st<strong>and</strong>ard-, duplex-, or high-reliability system (no PNC duplication):<br />

1. Administer carriers via add/change cabinet.<br />

2. Administer circuit packs via change circuit-pack.<br />

3. Administer connectivity <strong>and</strong> the facility options of the DS1 converter complex via add/<br />

change fiber-link.<br />

To administer a critical-reliability system (PNC duplication):<br />

1. Enable PNC duplication feature using the change system-parameter<br />

customer-option.<br />

2. Administer carriers via add/change cabinet.<br />

3. Administer circuit packs via change circuit-pack.<br />

4. Administer connectivity <strong>and</strong> the DS1 facility options of each DS1 converter complex via<br />

add/change fiber-link.<br />

5. Turn on PNC duplication via change system-parameter duplication.<br />

TN1654 Board Configuration Switch Settings<br />

The TN1654 DS1 converter circuit pack is field configurable for T1 or E1 operation so that a<br />

single board serves worldwide application. All four DS1 facilities are configured to either T1 or<br />

E1 as a group via an option switch located on the component side of the circuit pack. If T1<br />

operation is selected, four additional switches are used to select the framing mode for each<br />

facility. Each facility can be set to either D4 or ESF framing. If E1 operation is selected, the<br />

same four switches are used to select the E1 facility line termination impedance. The E1 line<br />

termination impedance for each facility can be set to either 120Ω for twisted-pair or 75Ω for<br />

coaxial wiring.<br />

T1 or E1 operation must also be administered for the TN1654 DS1 converter board on the<br />

fiber-link screen via the Bit Rate field. An <strong>error</strong> will be logged <strong>and</strong> an alarm will be raised if<br />

there is a T1/E1 inconsistency between the administered bit rate <strong>and</strong> the board option switch<br />

setting.<br />

The T1 facility framing mode <strong>and</strong> the E1 facility line termination impedance are defined by the<br />

option switch settings only. Administration of these values is not allowed. The fiber-link screen<br />

will display the selected option switch settings for each facility.<br />

DS1 Converter LEDs<br />

The TN574 board has seven LEDs on its faceplate. The TN1654 board has eleven LEDs on its<br />

faceplate. The top three system st<strong>and</strong>ard LEDs are used to provide an indication of the state of<br />

the DS1 converter board. These LEDs are under firmware control until the board has<br />

established a link to the server via the EI or SNI. Once the link is established, software controls<br />

the three LEDs. If the link breaks, the LEDs are again under firmware control.<br />

376 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers