VAL Congestion Controls<br />

The switch activates congestion controls on VAL when it detects buffers exceeding the<br />

threshold. The switch releases the congestion controls when the VAL reports that its buffer level<br />

has returned to normal levels.<br />

If congestion: Then the switch:<br />

Persists for a 14-minute interval Raises MINOR alarm<br />

Exhausts buffers Raises MINOR alarm<br />

Ceases for 12 minutes Retires MINOR alarm<br />

Error log entries <strong>and</strong> recommended actions<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location l<br />

1 (b) 0 SCOTCH Sync<br />

Looparound (#1275)<br />

MIN ON <strong>test</strong> port location l r 3<br />

257 (c) 0 WRN OFF<br />

3585 (d) 0, 1 TDM Looparound<br />

Test (#1285)<br />

MAJ ON <strong>test</strong> port location l r 3<br />

Notes:<br />

a. Error Type 0: there is no short <strong>test</strong> sequence for this MO. Every <strong>test</strong> is available in the long<br />

<strong>test</strong> sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: SCOTCH Synchronous Looparound Test (#1275) failed.<br />

1. Test the port (<strong>test</strong> port location long).<br />

2. See SCOTCH Synchronous Looparound Test (#1275) for repair procedures.<br />

c. Error Type 257: VAL port detected overrun or underrun condition that can indicate a<br />

hardware problem.<br />

1. Test for hardware problem (<strong>test</strong> port location long).<br />