19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

LEDs<br />

EXP-INTF (Expansion Interface Circuit Pack)<br />

3. After the SREPN slide switch has been restored to the normal position, <strong>test</strong> the<br />

connectivity to EI LAPD link, by using the suggested procedures outlined in this MO.<br />

4. After normal service is returned to the SREPN, the SRPPN will be in an alarmed state.<br />

This is normal for an SRPPN <strong>and</strong> indicates that the:<br />

● SRSwitch (TN2301) has disconnected it from its neighbor (EI in the SREPN)<br />

● SRPPN is no longer in control.<br />

Connectivity has been re-established between the EI in the SREPN <strong>and</strong> its counterpart EI circuit<br />

pack in the PN. The system is now in a normal EI configuration.<br />

SREPN Expansion Interface<br />

The EI circuit pack has red, green, <strong>and</strong> amber LEDs. The red <strong>and</strong> green LEDs display the<br />

st<strong>and</strong>ard conditions:<br />

● Red indicates an alarm condition.<br />

● Green indicates maintenance <strong>test</strong>ing in progress.<br />

The amber LED provides useful visual status information:<br />

● Active EI circuit packs:<br />

- Have their amber LED on solid (for an inter-EPN EI in a direct connect system)<br />

- Blink a pattern of 2 seconds on <strong>and</strong> 200 ms off.<br />

● The st<strong>and</strong>by PNC EI circuit packs should have their amber LEDs off.<br />

Another way to determine which PNC (<strong>and</strong> therefore, which EIs in an EPN) is active <strong>and</strong> which<br />

is st<strong>and</strong>by, use status port-network <strong>and</strong> status PNC.<br />

See Table 107: Expansion Interface Circuit Pack Amber LED Flashing States for the possible<br />

EI amber LED states.<br />

Table 107: Expansion Interface Circuit Pack Amber LED Flashing States 1 of 2<br />

Condition LED On LED Off<br />

Fiber Out-of-Frame (a) 0.1 second 0.1 second<br />

In Frame-No Neighbor (b) 0.5 second 0.5 second<br />

Expansion Interface Active (c) 2 second 0.2 second<br />

Expansion Interface Active (d) solid on never off<br />

1 of 2<br />

Issue 5 May 2009 433