PPP-PT (Control LAN Packet/Port)<br />

d. Error Type 513: PPP link lost end-to-end connectivity.<br />

1. Test for hardware problem (<strong>test</strong> port location long).<br />

2. Run TDM Looparound Test (#1285), <strong>and</strong> refer to its repair procedures if there is a<br />

hardware problem.<br />

If there is no hardware problem, the switch tries to re-establish PPP link.<br />

e. Error Type 769: Port received an invalid frame, which is greater than the maximum length,<br />

contains CRC <strong>error</strong>s, <strong>and</strong>/or violates the link level protocol.<br />

1. Test the port (<strong>test</strong> port location long).<br />

2. Refer to TDM Looparound Test (#1285) to verify repair.<br />

3. Clear the alarm (<strong>test</strong> port location long clear).<br />

f. Error Type 1281: the far end has requested a disconnect of a session on this link. This is a<br />

log-only <strong>error</strong>.<br />

g. Error Type 1537, 1538: some or all port sessions (sockets) are down:<br />

If the switch indicates that: Then it:<br />

Some of the sessions are down Raises off-board WARNING<br />

Every session is down Raises off-board MINOR alarm<br />

1. Test the port (<strong>test</strong> port location).<br />

2. See PPP Link Status Inquiry Test (#1279) for repair procedure to verify repair.<br />

h. Error Type 1793-1920: a socket was closed due to an <strong>error</strong>. Error Type indicates the<br />

application associated with this socket; Aux Data indicates the internal application number.<br />

Error Type Application<br />

1793 Unused<br />

1794 DCS<br />

1795 AUDIX<br />

1796 CMS<br />

1797 ISDN Gateway<br />

1798–1920 Reserved for future<br />

i. Error Type 2305-2816: a session is down. Aux Data indicates the session number. These<br />

are log-only <strong>error</strong>s:<br />

● Error Types 2305–2560 are for session numbers 1–256.<br />

● Error Types 2561–2816 are for session numbers 257–512.<br />

Issue 5 May 2009 785