Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Clock Health Inquiry Test (#46)<br />

The Clock Health Inquiry Test reads special data stored in memory to determine if the IPSI or<br />

Tone-Clock circuit pack had a loss of any of three clock types:<br />

● SYSCLK<br />

● SYSFM<br />

● SYSDCLK<br />

If this data indicates this IPSI or Tone-Clock circuit pack had a loss of any of these clocks, the<br />

<strong>test</strong> fails. TDM-CLK Error 1 indicates a suspect clock is at the edge of its specified frequency. If<br />

the circuit pack did not have a loss of clock, the <strong>test</strong> passes.<br />

This is not really a <strong>test</strong>, in the sense that it simply reports status held by the system, <strong>and</strong> does<br />

not generate new information or raise alarms. If this <strong>test</strong> fails with no Error Code, there is at<br />

least one Major alarm against an IPSI or Tone-Clock circuit pack. If this <strong>test</strong> fails with an Error<br />

Code of 1, there is at least one Minor off-board alarm against a TDM-CLK.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

Table 299: Clock Health Inquiry Test (#46) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

Retry the comm<strong>and</strong> at 11-minute intervals up to 5 times.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

1144 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />