Table 522: DSP Port TDM Looparound Test (#1380) 2 of 2<br />

Error<br />

Code<br />

2000<br />

2100<br />

2500<br />

Test<br />

Result<br />

Windows 2000 Reset Test (#1381)<br />

Windows 2000 Reset Test (#1381)<br />

ABORT Response to the <strong>test</strong> was not received in the allowed time.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2801 ABORT The TN802B/TN2302 Media Processor board has not been administered<br />

on the ip-interfaces screen.<br />

ANY FAIL The <strong>test</strong> did not detect the <strong>test</strong> tone through the looparound connection.<br />

1. Test the tone-clock in the port network that contains the media<br />

processor under <strong>test</strong>.<br />

2. If the tone-clock is healthy, <strong>test</strong> the media processor board again.<br />

3. If the <strong>test</strong> continues to fail, replace the media processor board.<br />

PASS The board is functioning properly.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

This <strong>test</strong> resets the TN802 MAPD circuit pack. The <strong>test</strong> is highly destructive <strong>and</strong> can be<br />

initiated only by a reset board location comm<strong>and</strong> on the TN802 circuit pack.<br />

This <strong>test</strong> runs on MEDPRO (Media Processor MAPD Circuit Pack).<br />

Table 523: Windows 2000 Reset Test (#1381) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources required for this <strong>test</strong> are not available.<br />

1. Retry reset board location at 1-minute intervals up to 5<br />

times.<br />

2 of 2<br />

1 of 2<br />

Issue 5 May 2009 1655