Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 376: Expansion Interface 2-Way Transmission Test (#241) 6 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

3 or 4 FAIL These failure <strong>codes</strong> only apply to a system equipped with a Center<br />

Stage Switch. They indicate that the <strong>test</strong> aborted or failed for the first<br />

connection from the EI board under <strong>test</strong> to another PN, <strong>and</strong> that the <strong>test</strong><br />

tone was detected correctly in one direction, but not the opposite<br />

direction when the connection was between the EI board under <strong>test</strong> <strong>and</strong><br />

a different PN than was used in the first connection.<br />

1. Run the <strong>test</strong> for the active Tone-Clocks on the PNs for which the<br />

defective EI board provides a link. This determines if the dial tone<br />

is being supplied.<br />

2. Perform the Fiber link fault isolation in Chapter 4: General<br />

troubleshooting in Maintenance Procedures for <strong>Avaya</strong> Aura<br />

Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432).<br />

FAIL The following failure <strong>codes</strong> only apply to a system equipped with an ATM<br />

Switch. The letters “MM” refer to the distant or far-end PN, <strong>and</strong> “NN” to<br />

the near-end ATM-EI under <strong>test</strong>.<br />

10MM FAIL The <strong>test</strong> tone was detected correctly in forward direction (data sent from<br />

the PN where the circuit pack under <strong>test</strong> resides <strong>and</strong> detected correctly<br />

in port network MM), but not the opposite direction.<br />

20MM FAIL The <strong>test</strong> tone was detected correctly in reverse direction (data sent from<br />

port network MM was detected correctly in the PN where the circuit pack<br />

under <strong>test</strong> resides), but not the opposite direction.<br />

30MM FAIL The <strong>test</strong> failed for the first connection from the ATM-EI board under <strong>test</strong> to<br />

another PN, <strong>and</strong> the <strong>test</strong> tone was detected correctly in the forward<br />

direction (data sent from the PN where the circuit pack under <strong>test</strong> resides<br />

was detected correctly in port network MM, but not the opposite<br />

direction).<br />

40MM FAIL The <strong>test</strong> failed for the first connection from the ATM-EI board under <strong>test</strong><br />

to another PN, <strong>and</strong> the <strong>test</strong> tone was detected correctly in the reverse<br />

direction (data sent from port network MM was detected correctly in the<br />

PN where the circuit pack under <strong>test</strong> resides), but not the opposite<br />

direction.<br />